LDC Inserting Electromagnetic Flowmeter

LDC Inserting Electromagnetic Flowmeter

  • Summary
  • Parameters
  • Size chart
  • Model order
  • Download
  • Communication

LDC Inserting Electromagnetic Flowmeter

Overview

LCD inserting electromagnetic flowmeter is suitable for measuring the volumetric flow of conductive liquid and seriflux (minimum conductivity is bigger than 20μs/cm) in sealed pipeline, such as clean water, sewage, slurry, pulp, food liquid, various solutions of acid, alkali and salt. It is also suitable for occasions such as wastewater treatment, surface treatment, washhouse, chemical industry (non-hazardous area), food industry, assistant factory, swimming pool, and so on.

 

Operating Principle

 

The measuring principle of LDC inserting electromagnetic flowmeter is based on Faraday’s law of electromagnetic induction. According to Faraday’s law, when the conductive liquid (minimum conductivity is bigger than 20μs/cm) contacts two electrodes and flows through pipeline, pressure can be measured between the two electrodes, and the pressure is proportional to flow velocity which can be converted to the flow quantity in unit time according to selected pipeline’s K coefficient.

Main Technical Parameters

 

Velocity Measurement Range

Flow rate 0.3~10m/s

Accuracy

it is ±1.5% of measured value when adopt field online calibration

it is ±2% of measured value when adopt standard K coefficient calibration

Repeatability

Indicator value 0.25%

Inside Nominal Diameter

100~3000mm

Operating Pressure

0.6~1.6Mpa

Working and Storing Temperature

0℃~+60℃

Working Power Source

220VAC/24VDC

Minimum Conductivity

20μs/cm

Material Contacting with Medium

Stainless steel 316L

Output Signal

Pulse, 4~20Ma (two-wire system), RS-485, Modbus, Hart protocol, etc.

Relative Humidity

<80%

Protective Level

IP65

Shell Material

Stainless steel 316L

 Ordering Models

Model

F

D

Illustration

Ball valve

Inside Nominal Diameter

LDG

 

 

Inserting electromagnetic flow meter

 

F

 

With ball valve

 

 

D100~300

100~300